UV LIGHT:

What is Ultraviolet?

Ultraviolet (UV) sterilization is used as a pretreatment and/or post treatment step to kill or inhibit growth of microorganisms, remove ozone, chlorine and trace organics and reduce total organic carbon (TOC). During UV sterilization, the water is exposed at a controlled rate to ultraviolet light waves. The bacteria absorb the UV radiation energy, which destroys or inactivates their DNA, thus preventing the bacteria from reproducing. UV systems may reduce 99% of bacteria in the water.

Specifications:

  • Lamp rated life time : 10,000 hrs
  • Each U.V lamp output 450 µW/cm2 at 1meter ; 1554 m.m length
  • Each U.V ballast = 150 Watts/hour electronics type
    Inlet / Outlet port (Inch) : FPT or Flange mount
  • Illuminating lamp holding cap to indicate if U.V lamp is working (illuminating in light blue color)
  • 304 Stainless steel UV chamber (316 S.S is also an option)
  • Polishing stainless steel reactor chamber.
  • Highest quality quartz sleeve to ensure maximum U.V output.

Monitoring devices (available on request for additional cost)

  • UV lamp electrical status
    1. UV lamp failure indication
    2. Non re-settable running timer
    3. UV intensity meter
    4. Circuit for remote alarm service
    5. Run dry water cut off switch
    6. UV lamp failed cut off switch

Our UV Collections

1. Light Commercial UV

U.V Model UV6F UV12F UV24F UV48F UV72F UV96F
Flow rate in R.O water 6GPM 12GPM 24GPM 48GPM 72GPM 96GPM
Flow rate in clean water 5GPM 10GPM 20GPM 40GPM 60GPM 80GPM
Electrical input (VAC) 220-240 220-240 220-240 220-240 220-240 220-240
Quantity of U.V lamp/quartz sleeve 1 1 1 2 3 4
U.V Output µW/cm2 @1Meter 1×53 1×110 1×230 2×230 3×230 4×230
Dimension WxHxL (Inch) 3×3x20 5×6x38 5×6x38 6×11x38 6×11x38 8×13x38
Inlet / Outlet (Inch) 1/2″ 1″ 1″ 1.5″ 2″ 2″

2. Large Commercial UV

U.V Model UV180 F UV360 F UV540 F UV720 F UV1080 F
Flow rate in distilled, DI, R.O water 180GPM 360 GPM 540 GPM 720 GPM 1,080GPM
Flow rate in clear, clean water 150 gpm 300gpm 450 gpm 600 gpm 900gpm
Electrical input (VAC)Single phase 220/240 220/240 220/240 220/240 220/240
Quantity of U.V lamps & quartz sleeves 4 8 12 16 24
Quantity of U.V ballast 4 8 12 16 24
Power consumption [watt/hour] 600 1,200 1,800 2,400 3,600
U.V lamp output (µW/cm2 @1m) 450 x4 450×8 450×12 450×16 450×24
Dimension of UV chamber WxHxL (c.m) 15×15x160 25×25x160 30×30x160 40×40x160 40×40x160
Inlet / Outlet (Inch) Female thread Or  Flange mount type 2” 4″ 5 “ 6 ” 8″

3. UV lamp for air sterilization

UV lamp used to sterilize air inside a room

230Vac/50Hz ; 15 Watts/hour UV lamp + a lamp holder + an internal ballast

4.UV lamp for water storage tank

UV lamp used to prevent airborne contamination in water storage tank

  • 18 Watts UV lamp module + screw mount + ballast + quartz sleeve
  • 85 Watts UV lamp module + screw mount + ballast + quartz sleeve

Spare parts for maintenance

Spare parts for maintenance

We are a one-stop supplier for all spare parts for UV sterilizer; UV lamp / Quartz sleeves / Ballasts / Lamp holder.


products and  prices: contact us

MEDIA FILTERS, FILTERS

What is media filter ?

There are two main types of filter media — a solid sieve which traps the solid particles, with or without the aid of filter paper, and a bed of granular material which retains the solid particles as it passes. The first type allows the solid particles, i.e. the residue, to be collected intact; the second type does not permit this. Also, when the solid particles are very fine, it is often cheaper and easier to discard the contaminated granules than to clean the solid sieve.

Filter Media
for water and waste water treatment

Arsenicide®
(Arsenic Removal)

Super Catalyst®
(Iron and Manganese Removal)

GAC
(Granular Activated Carbon)

Fluoricide®
(Fluoride Removal)

CFS®
(Ceramic Filtering Sand)

MEDIUM & BIG VOLUME TREATMENT

Filter media can be cleaned by rinsing with solvents or detergents. Alternatively, in engineering applications, such as swimming pool water treatment plants, they may be cleaned by backwashing.

Examples of the first type include filter paper used with a Buchner, Hirsch, filter funnel or other similar funnel. A sintered-glass funnel is often used in chemistry laboratories because it is able to trap very fine particles, while permitting the particles to be removed by a spatula.

Examples of the second type include filters at municipal and swimming pool water treatment plants, where the granular material is sand. In the laboratory, Celite or diatomaceous earth is packed in a Pasteur pipette (microscale) or loaded on top of a sintered-glass funnel to serve as the filter bed.

Automatic / Manual backwash filter tank

Filter tank / Fiberglass with P.E liner inside

Fiberglass filter tank can tolerate working pressure upto 100 psi without multi-port valve and can tolerate working pressure upto 55 psi complete installed with Multiport valve Tall dimension to give better filtration or deep bed filtration system

Complete with 6 ways Multi-port valve

  • Filter
  • Backwash
  • Rinsing
  • Recirculate
  • Waste
  • Close
Model number Tank diameter Bed depth Flow rate
DB650 65 c.m 75 c.m 15,000 LPH
DB750 75 c.m 85 c.m 22,500 LPH
DB900 90 c.m 100 c.m 30,000 LPH
DB1200 120 c.m 130 c.m 48,750 LPH

Large filter tank for deep bed filtration

Fiberglass filter tank can tolerate working pressure upto 100 psi without multi-port valve and can tolerate working pressure upto 55 psi complete installed with Multiport valve Tall dimension to give better filtration or deep bed filtration system.


SMALL FILTRATION SYSTEM

CANISTER FILTER FOR OYSTER / SMALL POND

Eheim Classic External Canister Filters

The ‘classic’ Eheim external power filters : high quality, reliable and highly efficient, adapted to small volumes as oyster ponds, or fresh water circuits for prawns, fish….

Suitable for Freshwater and Marine

These three “Plus” models come complete with filter media, hoses, taps, and fittings etc and are ready to set up and run

Filter Media not Supplied*

PUMPS

Diaphragm type booster pump

Model Product description Flow rate /water pressure
BP8000 48Vdc / 2 Amp booster pump 3.0 lpm @80 psi
BP7000 36Vdc / 1.5 amp booster pump 1.2 lpm @80 psi
BP9000 230Vac rotary vane pump 4.1 lpm @80 psi

Diaphragm type delivery pump

Model Product description Flow rate / water pressure
BP8000 230Vac or 110Vac delivery pump 4.8 LPM @20 psi
SP2088 230Vac or 115Vac delivery pump 11 LPM @20 ps

Self priming Vortex booster seawater pump

Model Power consumption Water flow rate & shut off head Port size
MAX 560 560 watts/hour 18,000 LPH & 16 meters 40 mm

Rotary Vane booster pump

Model Caliber Material Capacity (L/H) and power in deferent pressure (MPa) unit: horsepower
Body Rotor 1.05MPa 1.40MPa 1.75MPa
CP-233 3/8″ Brass S.S 245(0.25) 239(0.32) 233(0.39)
CP-377 3/8″ S.S S.S 390(0.36) 384(0.47) 377(0.57)
CP-1026 1/2″ S.S S.S 1032(0.78) 1029(1.00) 1026(1.22)